Showing results: 571 - 585 of 1156 items found.
-
CAPA500 -
Axiomtek Co., Ltd.
The CAPA500 features the LGA1151 socket 7th generation Intel® Core™ processor family (codename: Kaby Lake) with 35W TDP (thermal design power), as well as the Intel® H110 chipset (Q170 optional). The CAPA500 supports one 260-pin DDR4-2400 SO-DIMM with a memory capacity up to 16GB for extensive storage. The compact 3.5-inch embedded motherboard also offers display outputs through HDMI, VGA and LVDS for triple independent display applications. Moreover, the compact-sized embedded board runs on +12 VDC power, supporting auto power-on. It can operate at a wide range of temperatures from -20°C to 60°C under active thermal control. The 146 mm x 104 mm embedded SBC is suitable for IoT/M2M-related, industrial control, self-service terminal, digital signage, POS, kiosk and many other applications where high-speed processing and graphics performance under limited space is required.
-
Flyin Optronics Co., Ltd
Athermal AWG(AAWG) have equivalent performance to standard Thermal AWG(TAWG) but require no electrical power for stabilization. They can be used as direct replacements for Thin Film Filters(Filter type DWDM module) for cases where no power is available, also suitable for outdoor applications over -30 to +70 degree in access networks. Flyin’s Athermal AWG(AAWG) provide excellent optical performance, high reliability, ease of fiber handling and power saving solution in a compact package. Different input and output fibers, such as SM fibers, MM fibers and PM fiber can be selected to meet different applications. We can also offer different product packages, inluding special metal box and 19” 1U rackmount.
-
Virginia Panel Corporation
Rear termination is a SMA/ 3.5 mm/ 2.9 mm jackSMA for applications up to 18 GHz3.5 mm for applications up to 26.5 GHz2.92 mm for applications up to 40 GHz
-
TD-36S-AC -
Taylor Dynamometer, Inc.
Weight Capacity: 30,000 lb (13,608 kg) per axleRoll Brakes: Pneumatically-actuated discShipping Weight: 19,700 lb (8,936 kg)Capacity: 460 hp at 40 mph (343 kW at 64 kph)Rolls: 36 by 31 in. (915 by 787 mm) 2 fixed rollsPit Required Depth: 35 in. (889 mm)
-
Quad -
Sutter Instrument Company
Quad, the newest Sutter Instrument motorized micromanipulator, is easy-to use and features four independent axes. Each axis has a 25 mm range of motion, a digital display of position and an ROE control. The compact, intuitive controller takes up minimal bench space, is fan free and is easy to use.
-
Z5411 -
Copper Mountain Technologies
*Z5411 Calibration Kit, * Frequency Range: up to 54 GHz, * Impedance: 50 Ohm, * Connector Type: 2.4 mm female.
-
T4311 -
Copper Mountain Technologies
*T4311 Calibration Kit, * Frequency Range: up to 40 GHz, * Impedance: 50 Ohm, * Connector type: 2.92 mm female.
-
CK521A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK520A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK562A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK564A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK058F -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK058M -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
RK-410FS -
ADLINK Technology Inc.
*EIA RS-310C 19" rackmount standard*17.8 inch (451 mm) short depth*Three 5.25" and one 3.5" shock-resistant drive bays*Two front accessible USB connectors*Adjustable hold down bar for cards
-
YAV90Q04 -
6TL Engineering
The interface YAV90Q04 permits to connect two YAV90096 boards to one 192-Signal contacts Quadrapaddle module. As the Mini-D 50 connectors let 2 free pins (1 and 26), these pins are interconnected to a test point, with the possibility of be grounded. Cable P/N J6200540: Mini-D-50 to Mini-D-50 IDC connectors with 400 mm flat cable.